Skip to product information
1 of 7

Ceiling Mounted Dehumidifier DBA-UTC68 (Ultra Thin)

Ceiling Mounted Dehumidifier DBA-UTC68 (Ultra Thin)

Request a quote

Mon–Fri 09:30–18:00 HKT
  • Moisture Removal Rate: 68L/Day
  • Built-in water pump, head lift 1.8m
  • Built-in UV-C light
  • Automatic humidity control system
  • LCD touch control panel
  • Remote control
  • Efficient defrosted system
  • +/- 1% precision adjustable humidity
  • 1~24 hour timing function
  • Automatic fault diagnosis systems
  • Power off memory function
  • WiFi App control
  • RS485 Modbus (BMS, Smart Home Integration)
  • Remote on/off (dry contact)
  • Fault alarm function, outputs 230 Volts / 6A
  • Leak-detection cable signal input
  • Emergency Stop Button

 

View full details

Specification

ModelDBA-UTC68
Dehumidifying Capacity
(30°C 80%RH)
68L/Day
Dehumidifying Capacity
(26.7°C 60%RH)
42L/Day
Cover Area800-1000 sqft
Airflow500 CMH
Noise Level48 dB(A)
Static Pressure100 Pa
Rated Power880W
Max. Power1250W
Rated Current4.0A
Max. Current5.7A
Voltage220-240V~50Hz
Drain Height1.8m
Air Outlet/Inlet Flange⌀146mm
Drain Outlet SizeDN15
RefrigerantR410A/0.6kg
Operating Temperature5-40°C
Weight42kg
Dimension1010 × 500 × 240 mm
DBA Dehumidification Calculator

How much drying does your space need?

Start calculation Free · 30 seconds · no sign-up
Hong Kong humidity · Live
--% Relative humidity
DBA ceiling dehumidifier. whole house dehumidification system
DBA ceiling dehumidifier.wifi app

Ceiling / Wall Mounted Dehumidifier

Hidden in the ceiling, dry throughout

The unit is concealed above the false ceiling and carries dry air through ducting to every space. No tank to empty, no switching rooms on and off, and the right humidity held all year.

Ultra-slim body, no floor space used Concealed above the false ceiling, taking up no floor space at all.

The body is only 20 to 31 cm deep and sits above the false ceiling, installed the same way as a ducted air conditioner. All that shows in the room are a few supply grilles and a return grille. Where ceiling depth is tight, a wall-mounted model does the same job.

One unit, humidity controlled across every zone Dry air is carried through ducting to each space.

A single unit supports multiple supply outlets. In a home it sits above the corridor, with one outlet in the living room and one in each bedroom. In an office, clinic or hotel it can cover several rooms, or an entire floor.

Several times less energy than drying with air conditioning For an air conditioner, drying the air is only a side effect of cooling.

Once an air conditioner reaches its set temperature the compressor slows or stops, and moisture removal stops with it. That is why a fully air-conditioned space still tends to sit at 65 to 75% RH. Keeping a whole site dry that way means every unit in every zone running all day. A ceiling dehumidifier uses around a quarter of the energy and holds the space steady at 50 to 60%.

No tank to empty, shuts down if drainage fails A built-in pump clears the condensate. If drainage fails, the unit shuts itself down.

A floor-standing unit has to be opened up and emptied every time the tank fills, which is both time-consuming and physical work. The ceiling unit's built-in pump lifts condensate up to 1.8 m and clears it through a drain line automatically. If drainage fails and the internal drain pan fills, the unit stops on its own. For an extra layer of protection, a leak-detection cable can be wired to the unit's input, and water anywhere along its length stops the unit immediately.

Quiet operation, with UV-C sterilisation From 39 dB, quiet enough to forget it is there.

Inside are a horizontal compressor, a fan motor running on Japanese NSK bearings, and several layers of vibration isolation. On low fan speed there is little more than the sound of moving air, much like a ducted air conditioner. It suits spaces where noise matters, and keeps running right through trading or teaching hours. A UV-C lamp eliminates 99.9% of airborne bacteria and viruses, and the stainless steel filter washes out and goes straight back in.

Humidity held automatically, all year Control it from the LCD panel, the remote or your phone, and connect it to a smart home system or BMS over RS485 Modbus.

The wall-mounted LCD panel shows current humidity and temperature at all times. Set the target humidity, fan speed and schedule once, and the unit starts and stops on its own with nothing further to do. The Tuya Smart app handles remote monitoring and adjustment. For projects, an RS485 Modbus port and dry contacts allow integration with a BMS or PLC, and shutdown via the fire alarm system. On multi-unit sites, every unit can be viewed from a single interface.

ULTRA THIN CEILING DEHUMIDIFIER

FOR SLIM, SPACE-SAVING INSTALLS

As slim as 20cm, DBA ultra thin units hide inside the ceiling void and dry the whole space with 20 to 120L per day. Whisper-quiet, with built-in pump drainage and WiFi control. Ideal for apartments, homes, and low-clearance ceilings.

Learn More

COMMERCIAL CEILING DEHUMIDIFIER

FOR LARGE SPACES, DUCTED DEHUMIDIFICATION

High-capacity ducted units rated up to 550L per day with coverage to 5,000 sq ft, concealed above the ceiling. RS485 Modbus connects to your BMS. Built for warehouse, factory, offices, showrooms, and data centre.

Learn More

FRESH AIR CEILING DEHUMIDIFIER

FOR DRY, CLEAN, FRESH INDOOR AIR

Dehumidifies while bringing in fresh air, filtered through primary, active carbon, and HEPA layers. A 5-in-1 sensor tracks PM2.5, CO2, VOC, temperature, and humidity. Suited to homes, offices, basement and any sealed space that needs dry, fresh air.

Learn More
ly_dba-gew80ld-01_1744216726.jpg

WALL MOUNTED DEHUMIDIFIER

FOR COMPACT, FLEXIBLE WALL-MOUNTED DRYING

Compact and easy to install, DBA wall mounted units remove up to 80L of moisture per day and cover up to 800 sq ft, with no ceiling works required. Built-in pump drainage, precise ±1% humidity control, and RS485 connectivity. A practical fit for storerooms, laboratories, and galleries.

Learn More

Climate Control Unit

COOLING, HEATING, DRYING AND HUMIDIFYING

The condenser sits outdoors and the indoor section is concealed in the ceiling. Temperature and humidity are each set independently and held there all year, with only grilles showing in the space.

Learn More